Počet záznamov: 1
Development of the fast, simple and fully validated high performance liquid chromatographic method with diode array detector for quantification of testosterone esters in an oil-based injectable dosage form
Názov Development of the fast, simple and fully validated high performance liquid chromatographic method with diode array detector for quantification of testosterone esters in an oil-based injectable dosage form Aut.údaje Petr Kozlik, Barbora Tircova Autor Kozlík Petr (50%)
Spoluautori Benická Barbora 1983- (50%) UMBFP08 - Katedra chémie
Zdroj.dok. Steroids. Vol. 115 (2016), pp. 34-39. - New York : Elsevier Science Ltd., 2016 Kľúč.slová metódy - methods estery testosterón olej Jazyk dok. angličtina Krajina Spojené štáty Systematika 54 Anotácia Counterfeit steroids are available on the black market, ultimately to consumers who believe they are buying a legitimate pharmaceutical item from the labeled company. In many cases, counterfeit steroids can contain lower doses or some products can be overdosed. This can unwittingly expose users to a significant health risks. The mixture of testosterone propionate, phenylpropionate, isocaproate and decanoate in an oil-based injectable dosage form belongs to the one of the most misused illicit drugs by a variety of athletes. Kategória publikačnej činnosti ADC Číslo archívnej kópie 38967 Katal.org. BB301 - Univerzitná knižnica Univerzity Mateja Bela v Banskej Bystrici Báza dát xpca - PUBLIKAČNÁ ČINNOSŤ Odkazy PERIODIKÁ-Súborný záznam periodika nerozpoznaný
Počet záznamov: 1