Search results
Title Measurement of pressure converter with conductive ink Author info V. Novák ... [et al.] Author Novák Viktor 1982- (25%)
Co-authors Volf Jaromír 1954- (25%)
Novák Daniel 1952- (25%) UMBFP07 - Katedra techniky a technológií
Ryzhenko V. (25%)
Source document Trends in agricultural engineering : proceedings of 6th international conference, Praha, September 7th-9th 2016. S. 438-441. - Praha : Česká zemědělská univerzita v Praze, 2016 / Adamovský R. ; Aldoshin N. ; Trends in agricultural engineering Keywords conductive ink tactile sensors electrodes pressure converters Language English Country Czech Republic systematics 621.3 Annotation The paper presents characteristics and measurement process of conductive ink of type DZT-3K, acting as a converter of pressure into electrical signal. It mentions basic properties of the ink, including the explanation of the principle of function. Further it describes the measurement process with tactile sensors with circular electrodes of type PD. It studies the dependency of electrical resistance of the ink on the applied pressure. Various setups with different ink layer thicknesses are compared and their suitability to act as pressure converter is finally discussed Public work category AFC No. of Archival Copy 37049 Catal.org. BB301 - Univerzitná knižnica Univerzity Mateja Bela v Banskej Bystrici Database xpca - PUBLIKAČNÁ ČINNOSŤ Title Measurement of pressure distribution in knee joint replacement Author info J. Volf ... [et al.] Author Volf Jaromír 1954- (25%)
Co-authors Novák Viktor 1982- (25%)
Ryzhenko V. (25%)
Novák Daniel 1952- (25%) UMBFP07 - Katedra techniky a technológií
Source document Trends in agricultural engineering : proceedings of 6th international conference, Praha, September 7th-9th 2016. S. 685-689. - Praha : Česká zemědělská univerzita v Praze, 2016 / Adamovský R. ; Aldoshin N. ; Trends in agricultural engineering Keywords senzory - sensors transducer pressure distribution biomechanics knee joint replacement Language English Country Czech Republic Annotation The paper describes the measurement procedure of pressure distribution in knee arthroplasty and it verifies the accuracy of mathematical model of the pressure in the artificial joint. First it briefly presents the composition of the artificial joint. Then it describes in detail the measurement procedure, i.e. the measuring machine, which simulates a human step cycle, and the layout and type of used sensors. Finally, the measured pressure data are compared with those from the mathematical model and its accuracy is evaluated. Public work category AFC No. of Archival Copy 37056 Catal.org. BB301 - Univerzitná knižnica Univerzity Mateja Bela v Banskej Bystrici Database xpca - PUBLIKAČNÁ ČINNOSŤ